Question / Problem: 

In Kofax Capture Administration Module when publishing a Batch Class a similar error message is shown:

Publishing aborted: <YOR BATCH CLASSNAME>

[2] KFRS: The system cannot find the file specified.
 [CopyFile("C:\ProgramData\Kofax\Capture\pubtypes\Scripts\00000003.sbx,C:\ProgramData\Kofax\Capture\pubtypes\00000045.TMP\Scripts\00000003.sbx")] [Export(0); AscentCaptureSetup(1); Script(1)]


There were 0/1 successfully published batch classes.

Answer / Solution: 

Cause: A SBL script was created in Batch Class properties, Advanced Tab, Rubber Band OCR, Edit -> Recognition profiles. The pathes of the scripts for copying the SBL script to AdminDB folder are not correcly used. 

Solution:

Manually copy the Compiled SBX file, in our example "C:\ProgramData\Kofax\Capture\pubtypes\Scripts\00000003.sbx", to the PubTypes directory from the AdminDb/Scripts directory then, in our example "C:\ProgramData\Kofax\Capture\pubtypes\00000045.TMP\Scripts\00000003.sbx". Make sure to close the Windows Explorer folder under pubtypes. Republishing the Batch Class finishes without error.

Applies to:  

Product Version
Kofax Capture 9
Kofax Capture 10
Kofax Capture 11

 

 