Unable to open Message Connector Configuration Module from Windows Start menu using Edge
Article # 3049824 - Page views: 70
Issue
Unable to open Message Connector Configuration Module from Windows Start menu using the Edge.browser,
Cause
In Kofax Import Connector (KIC) 2.8 and 2.9 if the IE browser is uninstalled/disabled the Message Connector Configuration will not open.
Solution
There are three options available:
- The Message Connector Configuration can be accessed from the Message Connector Monitor | Configuration tools option. Requires Edge WebView2 runtimes installed
- Leave IE installed
- Upgrade to KIC 2.10 where this is resolved and install Edge Webview2 runtimes. This is documented in the KIC 2.10 Technical Specifications.
Level of Complexity
Easy
Applies to
Product | Version | Build | Environment | Hardware |
---|---|---|---|---|
Kofax Import Connector | 2.9 2.8 |
ALL | ALL | N/A |
References
N/A
Article # 3049824