Skip to main content
Kofax

EO/EE 5.7 - Server list of the Embedded object in System Manager is empty after applying System Manager hotfix

Article # 3015590 - Page views: 725

Problem Statement:

After applying System Manager hotfix EQ57-HF-321542-SysMgr, the virtual server name from a DCE HA setup did not display in the Server field on the Embedded device dialog in System Manager.

Cause:

This issue was introduced by System Manager hotfix EQ57-HF-309487-SysMgr and exists in EQ57-HF-312762-SysMgr, EQ57-HF-315401-SysMgr, and EQ57-HF-321542-SysMgr

Resolution:

Apply System Manager hotfix EQ57-HF-331326-SysMgr or newer version.