Issue

How to configure a KTA 7.6 or higher Scan Form to control the scanner's Imprinter Settings

 

Cause

KTA can be configured to control the scanner's Imprinter settings.  This can be useful for storing the last-used Imprinter Counter value and using that value to seed the starting Imprinter Counter value in the next scanning session.  

 

Solution

Video Demonstration of KTA Imprinter Settings Configuration

 

An example KTA Scan form with imprinting enabled can be downloaded from here.

 

To configure the Imprinter Settings in KTA:

  1. In the KTA Designer, select Forms from the User Interface menu
     
  2. Click the Scan Form link to open the Scan Form in the Form Designer
     
  3. Select the Actions tab
     
  4. Click New to create a new action
     
  5. In the Type field, select Same Page.
     
  6. Name the action SetImprinterString
     
  7. Click + to add a Target / Source/Value pair
     
  8. In the Target field dropdown, in the Form Field tab, expand ScanControl and select ScanControl.ImprinterString
     
  9. Use the Edit icon to manually type the desired imprinter string into the Source/Value field or use the dropdown menu to select a Form Variable or Global Variable whose value will populate the field.
     
  10. Click Add
     
  11. Click + to add a Target / Source/Value pair
     
  12. In the Target field dropdown, Form Field tab, expand ScanControl and select ScanControl.ImprinterIndexDigits
     
  13. Use the Edit icon to manually enter the number of counter digits to imprint into the Source/Value field and click Add.
     
  14. Click + to add a Target / Source/Value pair
     
  15. In the Target field dropdown, Form Field tab, expand ScanControl and select ScanControl.ImprinterIndexStep
     
  16. Use the Edit icon to manually enter 1 into the Source/Value field and click Add. (this will increment the counter every 1 page)
     
  17. Click + to add a Target / Source/Value pair
     
  18. In the Target field dropdown, in the Form Field tab, expand ScanControl and select ScanControl.ImprinterIndex
     
  19. Use the Edit icon to manually enter the counter start value into the Source/Value field, or use the dropdown menu to select a Form Variable or Global Variable whose value will populate the field.
     
  20. Click Add
     
  21. Click + to add a Target / Source/Value pair
     
  22. In the Target field dropdown, in the Form Field tab, expand ScanControl and select ScanControl.ImprinterRotation
     
  23. Use the Edit icon to enter 0, 90, 180, or 270 into the Source/Value field and click Add.  (This tells the scanner which rotation to use when imprinting each character on the page)
     
  24. Click + to add a Target / Source/Value pair
     
  25. In the Target field dropdown, in the Form Field tab, expand ScanControl and select ScanControl.ImprinterUnits
     
  26. Use the Edit icon to manually enter 0 (for inches), 1 (for centimeters), 2 (for picas), 3 (for points), 4 (for twips), 5 (for pixels), or 6 (for millimeters) into the Source/Value field and click Add.
     
  27. Click + to add a Target / Source/Value pair
     
  28. In the Target field dropdown, in the Form Field tab, expand ScanControl and select ScanControl.ImprinterVerticalOffset
     
  29. Use the Edit icon to manually enter the number of units from the leading edge of the page to start imprinting into the Source/Value field and click Add.
     
  30. Click + to add a Target / Source/Value pair
     
  31. In the Target field dropdown, in the Form Field tab, expand ScanControl and select ScanControl.ImprinterFontStyle
     
  32. Use the Edit icon to manually enter 1 (for normal), 8 (for large size), or 16 (for small size) into the Source/Value field and click Add.  Add 2 (for bold) or 4 (for italic) to the size value to combine these settings if the TWAIN driver supports it.
     
  33. Click Add to save the newly created SetImprinterString action to the Actions list.
     
  34. Click on the Design tab to return to the form
     
  35. Click the Lightning icon to the right of the form to open the Initialization and Events tab
     
  36. Click the Scan form loaded event
     
  37. Click Add
     
  38. Select the SetImprinterString action and click Done
     
  39. Click Save
     