Skip to main content
Kofax

Could not perform recognition due to an internal OmniPage error : Recognition process hard TimeOut

Article # 3045317 - Page views: 10

Issue

A job suspends at Classification/Extraction with the following error.

Could not perform recognition due to an internal OmniPage error: Recognition process hard TimeOut

 

Cause

The error occurs when the OmniPage engine cannot OCR a document within the non-configurable hard timeout threshold. 

This timeout threshold can be breached when OCRing documents with large dimensions.  For example, we have seen this error occur when OCRing multiple pages with dimensions 22.27 inches x 32.67 inches which are about the size of an A1 page.

 

Solution

Use a Document Conversion node to scale the pages down to A4 (or other) prior to OCRing the document.

 

Level of Complexity 

Easy

 

Applies to  

Product Version Build Environment Hardware
KTA 7.8+      

 

 

Article # 3045317
  • Was this article helpful?