Application login into [XXX] as station [YYY] failed

Article # 3038576 - Page views: 83

Question / Problem: 

Station(s) are not started, even if started manually. In TIS_Log file the following error message is shown:

Station Initialization failed: Application login into [XXX] as station [YYY] failed, Station login failed : Usage of feature 'ZZZZ' exceeded the maximum of 1 limited by license. Current usage is 1, requested increase count was 1. 

Answer / Solution: 

eFLOW is licensed by started stations not by user. In this case the station type that is started is already started once. This started station consumed the available one license for this station type. To start a second station of the type specified is not possible. To start a new station, the already started station needs to be closed. 

Applies to:  

Product Version
eFLOW 5
eFLOW 6
   

 

Article # 3038576